Model |
OM-1300 |
ALPHA+3A/A |
ALPHA+3V/V |
ALPHA+Hz |
ALPHA+RPM/MPM |
ALPHA+ 3VAF/VAF |
Parameters |
VLL, VLN, A, Hz, ON Hours |
A(avg), AR, AY, AB AMP A Field programmable CT (primary & secondary) |
VLL, VLN (avg & phase wise), Hz VOLT V Field programmable PT (primary & secondary) |
Frequency Hz 35-70Hz Class-0.2 |
RPM, MPM DC Vin-75mV or 100mV or 10V or 100V or 500V 0-20mA/4-20mA input 4- digit resolution(RPM) Field programmable (offset or full-scale value) |
VLL (avg & phase wise), A (avg & phase wise), Hz VLN, A, Hz Field programmable PT & CT (primary & secondary) |
Options |
2 Relay O/Ps for threshold on VLL, A, Hz (under or over)
|
2 Relay O/Ps for threshold on Amps (under or over) Transducer O/P (0-20mA/4-20mA/0-10V DC) for Amps(avg) |
2 Relay O/Ps for threshold on VLL, VLN, Hz (under or over) Transducer O/P (0-20mA/4-20mA/0-10V DC) for VLL, VLN, Hz(avg) |
2 Relay O/Ps for threshold on Hz (under or over) Transducer O/P (0-20mA/4-20mA/0-10V DC) for Hz (45-65Hz) |
|
2 Relay O/Ps for threshold on VLL(avg), A, Hz (under or over) Transducer O/P (0-20mA/4-20mA/0-10V DC) for VLL, VLN, A, Hz |
Size |
96X96X50 |
|||||
Cutout Size |
92X92 |
|||||
Accuracy |
1% of FS |
|||||
Supply |
80-300V AC |
|||||
Options: 40-300V DC, 80-300V AC/DC. |
||||||
Common Features |
True RMS Four-digit resolution with auto scaling Field programmable (state or delta or single phase) Average & phase wise information |
|||||
Additional Features |
Auto scrolling Optional direct measurement up to 20A. 60A or 100A (max) using hanging CTs Available in 0.8” 4-digit display |
Technical Specifications:
NOTE: Additional error of 0.05% of FS for meter input current below 500mA.
**********ECO FRIENDLY**********
Transducer Output:
ELMEASURE transducers are programmable which converts electrical parameters like voltage, current, frequency, power, power factor into DC current (0-20mA/4-20mA) programmable or DC voltage (0-1V). Applications: electrical, chemical, thermal power plants, etc. to monitor processed data either locally or remotely using SCADA by ELMEASURE or 3rd party.
Features & Benefits:
TRANSDUCER OUTPUT PROGRAMMABLE | |||||||
Transducer Models | Any One Output Programmable | Output Range Options | |||||
V | A | Hz | W | VA | PF | ||
ALPHA+3VAF | V | A | Hz | 0-20mA/4-20mA/0-1V DC | |||
ALPHA+3V | V | Hz | 0-20mA/4-20mA/0-1V DC | ||||
ALPHA+3A | A | 0-20mA/4-20mA/0-1V DC | |||||
ALPHA+Hz | Hz | 0-20mA/4-20mA/0-1V DC | |||||
LG+ 5110 | V | A | Hz | W | VA | PF | 0-20mA/4-20mA/0-1V DC/0-50V DC/0-10V DC |