Three Phase Energy Meters (LITTLE GENIUS PLUS)

Home / Energy Monitoring Instruments / Three Phase Energy Meters (LITTLE GENIUS PLUS)
Products Code : lg+5310, 5110, 3399, 1119, 1129

Need Advice?
Ask Our Experts!  +91 9376181613

Description

Model

LG+5310

LG+5110

LG+3399

LG+1129

LG+1119

Parameters

VLL, VLN, A (avg & phase wise), Hz, W, VA, PF (avg & phase wise), Wh, Hi-Amps, Load Hours, OLD registry(Wh, L.H.), ON time (non-resettable). Quick & easy navigation & programming. Displays more than 25 parameters

VLL, VLN, A (avg & phase wise), Hz, W, VA, PF (avg & phase wise), Wh, Load Hours, OLD registry (Wh, L.H.). Wh or VAh programmable with 7-digit resolution LCD, 6-digit resolution LED & 4-digit resolution for instantaneous parameters

PF, Wh or VAh, OLD registry, (VLL, VLN, A, Hz) or W or VA – any 2 programmable. Displays more than 15 parameters. 3 row LED display with 6 digits each.

PF, Wh, OLD registry, (VLL, VLN, A, Hz) or W or VA or PF or Wh – any 2 programmable.

Displays programmed parameter’s name and value for instantaneous parameters. Reduces complexity of stocking as this can be used for multiple measurement applications

Wh, (W or VA or PF or Wh) – any 1 programmable. Displays programmed parameter’s name and value for instantaneous parameters. Reduces complexity of stocking as this can be used for multiple measurement applications

Options

2 Relay O/Ps for threshold on VLL, A, Hz (under or over), PF (under), W (over), Wh (over), Phase missing

Programmable tripping time up to 180 sec. with hysteresis of 1%

 

1 Relay O/Ps for threshold on VLL, A, Hz (under or over), PF (under), W (over), Wh (over), Phase missing

LCD version – 2 relay O/Ps

Programmable tripping time up to 180 sec. with hysteresis of 1%

No optional features except RS485

 

 

Size

96X96X50

Cutout Size

92X92

Accuracy

1% of FS

Supply

80-300V AC

Common Features

True RMS

Field programmable

Optional Features

Communication with PCs, PLCs, DCS through an optional optically isolated RS485/232 serial interface

Pulse O/P – programmable pulse width of 50 to 500 ms. (For LG+ models only).

Programmable relay O/P. (See Product Selection Guide Table)

Features:

Accuracy: Class 1.0, Class 0.5 (Optional) ║ True RMS measurements ║ Simultaneous samplings of Volts & Amps ║ Energy display programmable-counter based or resolution based ║ Energy resetting at 999999 kVAh X Transformer Ratio ║ Positive energy accumulation even with reversed CT polarity, reverse lock programmable ║ User-programmable password protection ║ Auto scrolling ║ Auto scaling of kilo, mega, giga and decimal point ║ Low PT & CT burden ║ Front LED pulse 1250 imp/kWh of secondary input ║ Programmable PT & CT ratio up to 2000 MVA ║ Programmable kWh for meters with energy parameter ║ Wide measurement range – 10mA to 6A ║ Clearance & creepage distance meet safety standards ║ Finger touch proof terminals ║ Parameter name & value display using 7 segment LEDs ║ Display of 6 digits on each row for better readability ║ Field programmable (Star or Delta or Single-phase configuration).

Application Information:

LG+ series has optional optically isolated RS485 or pulse O/P which can be integrated into a process through PLC/DCS for online energy management. For pulse O/P, if the DCS/PLC has a self-excited 12V or 24V, external DC supply is not required.

Multiplication factor for counter based energy mode:

Full Scale Watts

√3V Pri LL x A Pri

0.4k to 4.0k

4.01k to 40k

40.1k to 400k

400.1k to 4000k

4M to 40M

40M to 400M

400M to 4000M

Multiplication Factor

0.01

0.1

1.0

10

100

1000

10000

Unit of Display

kWh

MWh

GWh

 

Energy Reset: 999999 kVAh X Transformer Ratio

Applicable Standards:

Test of insulation properties

IEC60060-1

Test of accuracy requirement

IEC62052-11

Test of electrical requirement

IEC62052-11

Radio interface suppression

CISPR22

Fast transient burst test

IEC61000-4.4

Damped oscillatory waves immunity test

IEC61000-4.12

Test of immunity to electro-magnetic RF fields

IEC61000-4.3

Test of immunity to conducted disturbances induced by radio frequency fields

IEC61000-4.6

Test of immunity to electrostatic discharges

IEC61000-4.2

Surge immunity test

IEC61000-4.5

Test of effect of climatic changes

IEC60068-2

Mechanical tests

IEC60068-2

Test of protection against dust and water

IEC60529

Test of resistance to heat and fire

IEC60695-2

Safety standards

IEC61010-1

Safety Specifications:

Designed to meet protection class III & pollution degree 2. Protection against shock by double insulation. Clearance and creepage meets as per UL61010 safety standard. Finger touch proof terminals.

Environment specifications:

Operating Temperature

-100C to +550C (140F to 1310F)

Storage Temperature

-250C to +700C (-130F to 1580F)

Humidity

5% to 95% non-condensing

Protection Index

IP51 (IP54 front option)

Recommended Wire Gauge

12 to 14 SWG (10 to 12 AWG)

 

PRODUCT SELECTION GUIDE
Model No. Basic Power Energy Accuracy Class 1.0/0.5 Optional Features
VLL (RYB) VLN (RYB) A (RYB) Hz W (RYB) PF (RYB) VA (RYB) kWh/kVAh #Load.Hrs./ON Hrs. OLD Energy RS232▼ RS485 Pulse O/P Digital O/P▼
LG+5310 VLL VLN A Hz W PF VA Wh LH & OH OLD √▪ 2
LG+5110 VLL VLN A Hz W PF VA Wh LH OLD √o 1
LG+3399 Wh   OLD    
LG+1119           OLD    
LG+1129   OLD    
▼Restricted Option # kWh/kVAh programmable on site ▪Zigbee communication option
oAnalog O/P
●LG+3399: Wh & PF any two parameters [Basic (VLL, VLN, A, Hz) or W or VA] programmable. LG+1119/L/D: Any one parameter [W or PF or VA or Wh] programmable

Get in touch

Subscribe with Us

Email id is required.

Copyright © Power Corporation. All rights reserved. | Designed & Developed By : www.onwebbox.com